Pre-Insulated Pipes
HomePre-Insulated Pipes
Pre-Insulated Pipes in UAE
Metalix offers pre-insulated pipes also called as insulated pipes which are used to maintain the temperature of the fluid in these pipes. Insulation provides the primary thermal resistance and prevents heat loss in chilled water systems. We supply state of art Pre-insulated Pipes for Chilled water application from district cooling/heating plant.
Presinsulation of Pipes are not required for running thru inside walls or basements that are heated. If the requirement is the prevention of freezing, then both hot- and cold-water pipes should be insulated. With the insulation, the cold water pipes can prevent this condensation
Presinsulation of Pipes are not required for running thru inside walls or basements that are heated. If the requirement is the prevention of freezing, then both hot- and cold-water pipes should be insulated. With the insulation, the cold water pipes can prevent this condensation

Insulation
Pre-Insulated system is made up of steel carrier pipe,100% CFC free polyurethane insulation foam and seamless solid wall HDPE Jacket. Steel Carrier Pipe may vary according to project specification from ERW or SAW or Seamless Pipes with wall thickness STD, SCH 40 and XS.
The thermal insulation will be rigid cellular 100% CFC-free Polyurethane or Polyisocyanurate foam, as per EN 253factory injected between core pipe and outer casing/protective Jacket, having a density of 35Kg/m3 (2.2lbs/ft3), 48Kg/m3 (3 lbs/ft3 ) or 60Kg/m3 (3.75 lbs/ft3 ) and thermal conductivity of 0.023 W/m.K (0.16Btu-in/hr ft2 oF) maximum, at mean temperature of 10 oC Typical operating temperature is between -17 to +120°C (0 to 250°F).
Each Pre-insulated pipe and fitting will have a factory applied protective coating or end seal applied to the exposed ends of the insulation for protection against moisture ingress.
The thermal insulation will be rigid cellular 100% CFC-free Polyurethane or Polyisocyanurate foam, as per EN 253factory injected between core pipe and outer casing/protective Jacket, having a density of 35Kg/m3 (2.2lbs/ft3), 48Kg/m3 (3 lbs/ft3 ) or 60Kg/m3 (3.75 lbs/ft3 ) and thermal conductivity of 0.023 W/m.K (0.16Btu-in/hr ft2 oF) maximum, at mean temperature of 10 oC Typical operating temperature is between -17 to +120°C (0 to 250°F).
Each Pre-insulated pipe and fitting will have a factory applied protective coating or end seal applied to the exposed ends of the insulation for protection against moisture ingress.
